Filter Results By:

Products

Applications

Manufacturers

Showing results: 76 - 90 of 90 items found.

  • Primary Current Injection Test Set

    T 2000 - Altanova Group

    T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.

  • LARGE CURRENT 1000A PRIMARY CURRENT INJECTION TEST SET

    TEST-901 - Beijing GFUVE Electronics Co.,Ltd.

    TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.

  • CT/VT Test System

    Eltel Industries

    Fully pre-wired comprehensive turn test system. *Suitable for CTs up to 6000A & VTs up to 132kV. * Precision to (0.005 class) internal multi-ratio standard CT. * Internal 4KA current source. * State-of-the-art Instrument Transformer Test Set AITTS-98 with computer & printer interfaces. * Electronic potential divider facilitates testing any VT ratio upto 132kV. * Current & potential burdens.

  • 904 Benchtop Six Phase 30A

    Weshine Electric Manufacturing Co., Ltd

    1. The instrument has standard six phase voltage and six phase current output. It can test not only traditional relays andprotection devices, but also modern micro-computer protection devices, especially for transformer differential protection and standby automatic switching device. The test is more convenient and perfect.2. can be connected to laptop (optional) to run.Laptops and industrial computers use the same set of software, so there is no need to relearn the operation method.

  • Temperature Rise Test Panel

    2000A - SCR ELEKTRONIKS

    SCR ELEKTRONIKS have developed “TEMPERATURE RISE TEST BENCH FOR MEDIUM VOLTAGE SWITCH BOARDS” to measure rise in temperature at various points as mentioned in standard at junctions. The set-up consists of a True RMS Constant Current Source (to maintain the Current within + / - 1 % of set value with Digital Indication), PC based control system, Temperature data logging on PC, Servo-Controller and other indications. Digital voltmeter Primary Voltage) indicates the position of auto transformer (variac).

  • Transformer Turns Ratio Testers

    IBEKO Power AB

    Transformer turns ratio testers from TRT series are DV Power instruments mainly designed for the measurement of power transformer turns ratio. Also, they measure transformer excitation current and phase shift. Special tests, such as automatic vector group detection and magnetic balance, can be performed on three-phase transformers and three-phase autotransformers.All models, except TRT03 series, have a built-in true three-phase power source, which is necessary for testing turns ratio of transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.DV Power turns ratio testers can output various test voltages for different applications. From the extremely low test voltage of 1 V AC that enables turns ratio verification of the majority of current transformers, up to the highest test voltage of 500 V AC that provides the most accurate turns ratio testing of power transformers used in power generation and transmission. By using the external booster, test voltage increases up to 5 kV AC in order to successfully test capacitive voltage transformers.All DV Power turns ratio testers have a built-in tap changer control unit. Because of that, it is possible to control the on-load tap changer (OLTC) directly from the device. In order to make the most out of this feature, the instrument and included DV-Win software can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option significantly facilitates and shortens the turns ratio testing time.TRT turns ratio testers use the same set of cables as three-phase winding ohmmeter & tap changer analyzers from the TWA series. Consequently, it enables one-time cable setup for performing eight tests:turns ratioexcitation currentphase anglemagnetic balancevector group detectionwinding resistanceon-load tap changer DVtestand demagnetization.

  • Turns Ratio Testers

    TRT Advanced Series - IBEKO Power AB

    TRT Advanced series is the newest DV Power solution for transformer turns ratio measurement. Besides its main application, each turns ratio tester from this series also measures transformer excitation current and phase shift. Furthermore, all models perform automatic vector group detection and magnetic balance on three-phase transformers and three-phase autotransformers. They have a built-in true three-phase power source. For that reason, they can test transformers with special configurations, such as phase-shifting, rectifier, arc-furnace, traction transformers, etc.The instruments can output test voltages from 1 V AC to 500 V AC, depending on the model. With the highest test voltage 500 V AC, TRT500 provides the most accurate turns ratio testing of power transformers used in power generation and transmission. The output test voltage of TRT500 can be boosted to 5 kV AC using the external CVT20 extension transformer. This application is specially designed for testing turns ratio of capacitive voltage transformers. The other three models, TRT400, TRT250, and TRT100 can output up to 400 V, 250 V, and 170 V respectively. The low test voltage of 1 V AC enables turns ratio verification of current transformers.TRT500 is equipped with a large 10.1” graphical touch screen display. Other models, (TRT400, TRT250, TRT100) have 7” graphical touch screen display. Besides making the interface much more user-friendly compared to older turns ratio testers, it also brings certain options that were previously available only with DV-Win software. The most important are test templates and automatic test mode. Users can simply create test templates, store them in the instrument’s memory, and load when in the field with just a few clicks.This turns ratio test set, as well as all other DV Power turns ratio testers, has a built-in tap changer control unit. It enables remote control of an on-load tap changer (OLTC) directly from the instrument. In order to make the most out of this feature, the instrument can be programmed to do everything automatically – running turns ratio tests, changing OLTC tap positions, and saving results. This option, especially in combination with test templates, significantly facilitates and shortens the turns ratio testing time. Automatic test mode minimizes human errors, which makes the measurement more reliable.

  • Compact Automatic Voltage Regulating Relay With Built- In TPI

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Compact Automatic Voltage Regulating Relays

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Automatic Voltage Regulating Relay- Standard Model

    Neutronics Manufacturing Co.

    NMC’s Microcontroller based Automatic Voltage Regulating Relays (AVR Relays) are latest technology based Relays used for regulating the secondary voltage of Power Transformers with On Load Tap Changer (OLTC). The Parameter settings are made through the front panel keys & are stored in NVRAM. Independent time delays can be set for first control pulse & subsequent pulses. Built-in Tap displays Tap number of Power Transformer. OLTC is blocked for UV, OV, OC, CF, Min/Max Tap Positions & Tap Fail . in manual mode, Tap Raise/Lower can be achieved through front keys. In TEST mode, Relays, Display and LED indications can be checked. A pair of contacts are available for Raise, Lower, UV, OV, Manual Mode, CF, TF & OC. There are two nos. of 5 Amps C.T.’s available, one for the Over Current blocking and L.D.C. & other for measuring the Current.

  • Advanced Primary Injection Test Set

    PI-2500 - ETI Precision

    The PI-2500 is a versatile and technologically advanced primary injection tester capable of testing circuit breakers up to 2000 amperes frame size. It incorporates a low-impedance output transformer with dual secondaries to provide optimal impedance matching to a wide range of breaker sizes. High-capacity internal fan cooling allows maximum utilization of the output transformer and faster recovery after overload conditions. It is housed in a rugged aluminum frame enclosure with removable sides allowing easy access to all internal components to facilitate ease of service and maintenance. The output of the test set is controlled by means of a proven SCR controller. This provides precise initial phase angle control to reduce DC offset for inductive loads and more consistent pulse currents.

  • Relay Test Set

    RNT-5A - Neutronics Manufacturing Co.

    This is a portable testing kit in one unit, suitable for testing protective relay, over current relay, earth fault relay, protective device, circuit breaker, tripping coils etc.The set is designed for both laboratory and field use. TECHNICAL FEATURES: INPUT : 230 Volts, single phase, 50Hz. AC. OUTPUTS : : 1) Current Output: a) 0- 1Amp. At 6/60Volts. (Continuous duty). b) 0- 5 Amps. At 6/60 Volts. (Continuous duty). c) 0- 10 Amps. At 6/60 Volts. (Continuous duty). d) 0- 20 Amps. At 6 Volts. (for30 min. duty). e) 0- 50 Amps. At 6Volts. (For 10 min. duty). f) 0-100 Amps. At 6 volts. (For10 min. duty). g) 0-200 Amps at 6Volts. (For 30 sec. duty). Current output is continuously variable and the output is taken out through a multi range C.T. The secondary is connected to an ammeter scaled in 0 to 100%. Output current range 1Amp. To 20Amps. Are selected by current range selector switch with common output terminals and for other three ranges three brass terminals are provided of proper ratting. 2) AC Voltage Output: Continuously variable 0 -230V AC. Capacity- 240VA (Max). OR DC Voltage Output: Continuously Variable 0-240V DC. Capacity-240VA.(max). One change over switch should be provided for selection of Volt. Meter for AC or DC voltage output & either AC or Dc voltage should be available at a time. 3) Time Measurement: 0-9.999Secs. & 0-99.99Secs. in two ranges. Accuracy: 1% CURRENT CIRCUIT: Loading transformer: Double winding loading transformer of suitable burden to provided corresponding current output specified before. One change over switch in current ckt. To be provided for voltage selection i.e. selection of 10volt. Or 50volt. Measuring CT: Multi ratio wound primary current transformer Ratio : 1-5-10-20-50-100-200A/5A. Variable auto transformer: For smooth variation of current output at various ranges selected. Tripping circuit: The current output will be cutoff incase of any overload for the range 200A or even if the relay under test actuated.

  • Automatic Instrument Transformer Test Set

    Eltel Industries

    *ARM 9 processor controlled measurements*Measures total burden connected to test sample*Internal data storage facility upto 1 lakh readings*Digital display of test results on 800 x 480 TFT color display.*Latest IEC 61869 / ANSI C57.13-2008 / IS-2705 standards incorporated*VGA Port to interface with bigger display / monitor*Both Voltage & Current Transformer testing with one test set*5 and 1 Amp CT testing using either 5 or 1 Amp standard CT*Identifies ANSI, IEC, IS-P, IS-PR, BS, BS-S, IEC-S, IS, IS-S, AS, AS-M, AS-ME standards for CT & VT*USB memory storage*Available in three versions: AITTS Plus , ACTTS Plus & AVTTS Plus

  • Microohmmeter

    MMR-6500 - Sonel S.A.

    The MMR-6500 digital meter is designed for measuring low resistances with a stabilised current of up to 100 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6500 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.

  • Microohmmeter

    MMR-6700 - Sonel S.A.

    The MMR-6700 digital meter is designed for measuring low resistances with a stabilised current of up to 200 A. The use of test clamps enables the safe measurement of breakers (high-, medium- and lowvoltage), isolators and other components earthed on both sides. The MMR-6700 series meters are equipped with a unique module in their class that measures inductive components which have a current of up to 10 A, enabling the winding resistance of motors, transformers and other inductive components to be measured. Another useful function is the temperature measurement and the automatic compensation of results with relation to the measured temperature or temperature set by the user. The system is completed with a recorder function. Special measuring algorithms and additional functions allow an appropriate measuring method to be chosen depending on the measured component and measurement conditions, thus, widening the application areas of the meter. The state-of-the-art user interface, various communication interfaces, wireless communication and communication with the computer, printer, 2D code reader are integrals features which enable full, comfortable and intuitive management of not only measurements and their results but also ID data of measured components.

Get Help